The IPT series, a high-frequency sine wave inverter, adopts a fully digital intelligent design and voltage-current dual closed-loop control algorithm. Featured with fast response, high conversion efficiency, low Total Harmonic Distortion(THD), and high reliability running, this series can be widely used in the DC-AC off-grid systems (such as vehicle systems, security monitoring systems, emergency lighting systems, household power systems, field power systems, and other systems requiring higher power quality).
Special features
- Pure sine wave output
- Input to output electrical isolation
- Output power factor up to 1
- Input Protection: Low-voltage, Over-voltage
- Output Protection: Overload, Short circuit, Overheating
- RS485 com. port to realize remote monitoring
- External switch design, matched with EPEVER products, to expand inverter control function and reduce power consumption
- EN/EC62109-1/2, EN61000-6-2/4, and FCC approved
Technical Specifications
Model |
IPT1000-42 |
IPT1500-42 |
IPT2000-42 |
IPT3000-42 |
IPT4000-42 |
IPT5000-42 |
EAN Code |
4260558574743 |
4260558574774 |
4260558574675 |
4260558574668 |
4260558574682 |
4260558574699 |
Article number |
3421000 |
3421500 |
3422000 |
3423000 |
3424000 |
3425000 |
Continuous output power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
Surge power |
2000W@5S |
3000W@5S |
4000W@5S |
6000W@5S |
8000W@5S |
8000W@5S |
Surge current when power on1
|
< 35A |
< 50A |
< 50A |
< 65A |
< 65A |
< 65A |
Output voltage |
220VAC/230VAC/240VAC(±3%) |
220VAC (±3%); 230VAC (-6%~+3%); 240VAC (-9%~+3%) |
Output frequency |
50/60Hz ± 0.2% |
Output wave |
Pure Sine Wave |
Output distortion THD |
THD ≤ 3% (Resistive load) |
Load power factor |
0.2 ~ 1 (Load power ≤ Continuous output power) |
Rated input voltage |
48VDC |
Input voltage range |
43.2 ~ 64.0VDC |
Rated output efficiency 2
|
> 92.0% |
> 92.5% |
> 92.5% |
> 92.5% |
> 91.0% |
> 91.0% |
Max. output efficiency 3
|
> 93.0% (40% loads) |
> 94.0% (30% loads) |
> 94.5% (30% loads) |
> 94.5% (30% loads) |
> 94.0% (30% loads) |
> 94.0% (30% loads) |
Idle current |
< 0.10A |
< 0.10A |
< 0.10A |
< 0.10A |
< 0.10A |
< 0.10A |
No-load current |
< 0.4A |
< 0.5A |
< 0.5A |
< 0.5A |
< 0.6A |
< 0.8A |
RS485 com. port |
5VDC/200mA |
Mechanical parameters |
|
Input terminal |
M6 |
M6 |
M6 |
M6 |
M6 |
M6 |
Dimension (L x W x H)mm |
332 × 228 × 118 |
387 × 228 × 118 |
421 × 228 × 118 |
491 × 228 × 118 |
516 × 228 × 118 |
532 × 228 × 118 |
Mounting size (L x W)mm |
306 × 145 |
361 × 145 |
395 × 145 |
465 × 145 |
490 × 145 |
505 × 145 |
Mounting hole size |
Φ6mm |
Φ6mm |
Φ6mm |
Φ6mm |
Φ6mm |
Φ6mm |
Net Weight |
4.5kg |
5.2kg |
5.8kg |
6.8kg |
7.8kg |
8.5kg |
Environment parameters |
|
Working temperature |
-20℃ ~ +60℃ (Refer to the Derating Curve) |
Storage temperature |
-35 ℃ ~ +70 ℃ |
Relative humidity |
≤ 95% (N.C.) |
Enclosure |
IP20 |
Altitude |
< 5000m (If the altitude exceeds 1000 meters, the rated power will be reduced according to IEC62040.) |
Certification |
|
Safety |
EN/IEC62109-1, UL458 (Products with 12/24V input voltage support), CSA C22.2#107.1 |
EMC(Electromagnetic compatibility) |
EN61000-6-2/EN61000-6-4,FCC 47 CFR Part 15, Subpart A |
RoHS |
IEC62321-3-1 |
1 The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For other products, the actual surge current prevails.
2 It means the rated output efficiency when the load power equals the "continuous output power" under the rated DC input voltage.
3 It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage.
Product safety information
Manufacturer information:
SolarV GmbH
Am Kronberger Hang 2
Hessen
Schwalbach am Taunus, Deutschland, 65824
info@solarv.de
www.solarv.de