Product Features
Advanced MPPT technology, with tracking efficiency no less than 99.5% Ultra-fast-tracking speed and guaranteed tracking efficiency Accurate recognition and tracking of multiple-peaks maximum power point High quality components, perfecting system performance, with maximum conversion efficiency of 98% Charging power and current limitation function Wide MPP operating voltage range Compatible with lead-acid and lithium-ion batteries Battery temperature compensation function (only for Lead-acid battery) Real-time energy statistics function Overheating power reduction function Multiple load work modes International famous brands of ST and IR'scomponents of high quality and low failure rate areused, which can ensure the product’s service life Full-load operation without any drop-in capacity within the range of working environment temperature With RS-485 communication bus interface and Modbus communication protocol. The communication port adopts professional protection chip Monitor and set the parameters via mobile phone APP or PC software Extensive electronic protection
Protection function
PV Over Current/power PV Short Circuit PV Reverse Polarity Night Reverse Charging Battery Reverse Polarity Battery Over Voltage Battery Over Discharge Battery Overheating Lithium Battery Low Temperature Load Short Circuit Load Overload Controller Overheating TVS High Voltage Transients
Technical Specifications
Model of manufacturer
Tracer3210AN
EAN
4260558570448
Article number
2102430
System nominal voltage
12/24V DC Auto①
Related charge current
30A
Related discharge current
30A
Battery voltage range
8~32V
Max. PV open circuit voltage
100V② 92V③
MPP voltage range
(Battery voltage +2)~72V
Max. PV input power
390W/12V 780W/24V
Max. PV Array power
580W/12V 1170W/24V
Self-consumption
≤12mA
Temperature compensate coefficient
-3mV/℃/2V (Default)④
Grounding
Negativ
RS485 interface
5VDC/100mA
Working environment temperature
-25°C bis +45°C
Enclosure
IP30
Dimension
228 * 164 * 55mm
Weight
1,26kg
① When a lithium-ion battery is used, the system voltage can’t be identified automatically.② At minimum operating environment temperature.③ At 25°C environment temperature.④ When a lithium-ion battery is used, the temperature compensate coefficient is 0.
Product safety information
Manufacturer information:
SolarV GmbH Am Kronberger Hang 2
Hessen Schwalbach am Taunus, Deutschland, 65824
info@solarv.de www.solarv.de
Which charge controller of EPEVER support lithium battery?
The MPPT Tracer AN, XTRA N and Triron N series solar charge controllers can be configured to charge lithium battery storage devices. but the parameters of lithium battery must be set by app, PC software and MT50 display. It is important that these storage devices have their own battery management system (BMS), which does not require communication with the solar charge controller.
What are grounding specifications for Lithium Battery Solar System?
The controllers of EPEVER are divided into the common positive and common negative. If the common positive BMS and negative ground controller are used together, it would cause damage to the controller or lithium battery. Therefore, when configuring a lithium battery solar off-grid system, please select the corresponding controller according to the BMS specifications (a lithium battery with a common anode selects a controller with a common anode.)
Can the charge controllers of EPEVER be connected in parallel?
Only the MPPT Tracer 50A-100A charge controllers support up to 6 units in prallel by using a parallel adapter (PAL-ADP-50AN). After adding the parallel adapter, the charging current of each controller can be adjusted automatically in real-time. The charging operation status of the controller is automatically adjusted according to the battery charging state to improve the redundancy of the entire photovoltaic system.
What is multi-stage charging (bulk charging, constant charging and float charging)?
Bulk charging
In this stage, the battery voltage has not reached constant voltage (Equalize or Boost Voltage) yet. The controller operates in constant current mode, delivering its maximum current to the batteries (MPPT Charging). When the battery voltage reaches a preset value, it will switch to Constant Charging.
Constant charging
When the battery voltage reaches the constant voltage setpoint, the controller will start to operate in constant charging mode, and this process is no longer MPPT charging. In the meantime, the charging current will drop gradually, and the process is not the MPPT charging. The Constant Charging has 2 stages, equalize, and boost. These two stages are not carried out constantly in a full charge process to avoid too much gas precipitation or overheating of the battery. Among them, equalize charging starts only on the 28th of each month.
a) Boost charging
The Boost stage maintains 2 hours in default (user can adjust the constant time and preset value of boost voltage according to demand). When the duration reaches the set value, the system will switch to floating charging.
b) Equalize charging
Some types of batteries benefit from equalizing charges regularly, which can stir electrolytes, balance battery voltage, and accomplish chemical reactions. Equalizing charge increases battery voltage, higher than the standard complement voltage, which gasifies the battery electrolyte.
The equalizing charging time is also 2h by default (settable). Equalize charge and boost charge are not carried out constantly in a full charge process to avoid too much gas precipitation or overheating of the battery.
Floating charging
After the Constant voltage stage, the controller will reduce the charging current to the Float Voltage setpoint. This stage will have no more chemical reactions, and all the charge current transforms into heat and gas at this time. Then the controller reduces the voltage to the floating stage, charging with a smaller voltage and current. It will reduce the temperature of the battery and prevent the gassing and charging the battery slightly at the same time.
How to set lithium battery parameters in “USER” mode?
When selecting the “User” type to set the parameters of the lithium battery, the following precautions must be followed:
1) The control voltage parameters must be set by referring to the specifications of the lithium battery protection board, and the accuracy requirement of the lithium battery protection board is not greater than 0.2V. If the deviation is greater than 0.2V, which causes an abnormality in the system, EPEVER shall not directly or indirectly be liable for any loss or danger.
2) The temperature compensation coefficient is changed to 0;
3) The equalized voltage and the boosted voltage are the same, and the time is the same;
4) Each voltage point must follow the following logic.
a. Overvoltage Disconnect Voltage > Over-Charging Protection Voltage(from BMS) +0.2V;
b. Overvoltage Disconnect Voltage > Overvoltage Reconnect Voltage ≥ Charging Limit Voltage ≥ Equalize Charging Voltage = Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage;
c. Low-voltage Reconnect Voltage > Low-voltage Disconnect Voltage ≥ Discharge Limit Voltage;
d. Under-voltage Warning Reconnect Voltage > Under-voltage Warning Voltage ≥ Discharge Limit Voltage;
e. Low-voltage Disconnect Voltage > Over-discharge Protection Voltage(from BMS) +0.2V;
Warning: Please choose a lithium battery controller for lithium battery applications. It is not recommended to use a non-lithium battery controller to charge the lithium battery. If the system fails due to the use of a mismatched controller, EPEVER shall not directly or indirectly be liable for any loss or danger.