Use solar power as you generate it, or store it for later
The EPEVER ELS6K is a single-phase hybrid inverter for residential PV systems with 48 V battery storage. In self-consumption mode, solar power supplies the connected loads first. Surplus energy charges a compatible battery, so you can use it later in the evening or when solar generation is low. During a power outage, a dedicated backup output supplies the circuits connected to it.
Dual MPPT for flexible string design
The two MPP trackers control one PV string each, independently of one another. This is particularly useful when panels are installed on roof sections with different orientations. The ELS6K supports up to 9,000 W of PV input power and an MPPT voltage range of 100 to 550 V.
48 V battery connection with up to 120 A
The inverter supports compatible lithium and lead-acid batteries with a voltage range of 42 to 63 V. The maximum charging current and maximum discharging current are both 120 A. CAN and RS485 interfaces enable communication with a compatible battery management system.
Backup power for selected loads
During a grid outage, the ELS6K switches to backup power in less than 10 ms. The dedicated output is rated at 6,000 VA in off-grid operation. Backup runtime depends on available solar generation, the battery's state of charge and the connected load.
Passive cooling and IP65 protection
The fanless enclosure is designed for wall mounting. The inverter features an integrated DC isolator and surge protection on both the DC and AC sides. A compatible external communications module enables system monitoring via the app.
Key Features
-
Scheduled charging and discharging. Set charge and discharge times and power levels to suit your energy usage.
-
Peak shaving. When demand exceeds the configured grid import limit, the PV array and battery can supply the additional power.
-
Configurable multifunction port. Depending on the system configuration, the port can be used to connect a generator, control a load or AC-couple a compatible PV inverter.
-
Single-phase parallel operation. The manufacturer supports up to six units operating in parallel in a system designed for this configuration.
Technical Specifications
| Model |
EPEVER ELS6K |
| Battery Input |
| Battery type |
Lithium or lead-acid |
| Battery voltage range |
42–63 V DC |
| Nominal battery voltage |
48 V DC |
| Battery charging mode |
Three-stage charging or BMS-controlled charging |
| Maximum charge and discharge current |
120 A |
| PV Input |
| Maximum PV input power |
9,000 W |
| Maximum PV input voltage |
580 V DC |
| MPPT voltage range |
100–550 V DC |
| Start-up voltage |
100 V DC |
| Rated input voltage |
360 V DC |
| Maximum input current per MPPT |
16 A |
| Maximum short-circuit current per MPPT |
19.2 A |
| MPP trackers / strings per tracker |
2 MPPTs / 1 string per tracker |
| AC Output (Grid-Tied Operation) |
| Maximum apparent output power |
6,600 VA |
| Rated output voltage |
230 V AC, single-phase |
| Rated output frequency |
50 Hz |
| Maximum output current |
28.6 A |
| Maximum grid input current |
55 A |
| Power factor |
0.99 (adjustable from 0.8 lagging to 0.8 leading) |
| Total harmonic current distortion (THDi) at rated power |
< 3% |
| AC Output (Off-Grid Operation) |
| Rated apparent output power |
6,000 VA |
| Peak output power |
150% of rated power for 60 s |
| Overload capacity |
125% of rated power for 300 s |
| Transfer time |
< 10 ms |
| Rated output current |
26.1 A |
| Rated output voltage |
230 V AC |
| Rated output frequency |
50 or 60 Hz (±0.5%) |
| Total harmonic voltage distortion (THDv) with a linear load |
< 3% |
| Efficiency |
| Maximum efficiency |
98% |
| European weighted efficiency |
97.5% |
| Maximum battery-to-AC efficiency |
94.6% |
| MPPT efficiency |
99.9% |
| General Specifications |
| Protection functions |
PV reverse-polarity protection, PV insulation monitoring, grid monitoring, AC overcurrent protection, overtemperature protection, anti-islanding protection and residual current monitoring |
| DC isolator |
Integrated |
| Arc-fault circuit interrupter (AFCI) |
Optional |
| Surge protection |
DC Type 2 / AC Type 3 |
| PV rapid shutdown (RSD) |
Optional |
| Automatic generator start |
Two-wire start |
| Operating temperature |
−30 to +60 °C, with power derating above +45 °C |
| Relative humidity |
0–95%, non-condensing |
| Maximum operating altitude |
4,000 m, with power derating above 2,000 m |
| Cooling |
Passive cooling |
| User interface |
LED indicators and app |
| BMS communication |
RS485 / CAN |
| Energy meter communication |
RS485 |
| System monitoring |
Wi-Fi / Bluetooth via an external communications module |
| Net weight |
28.1 kg |
| Dimensions (W × H × D) |
558.1 × 455.1 × 222.5 mm |
| Noise emissions |
< 25 dB |
| Topology |
High-frequency isolation on the battery side |
| Standby power consumption |
< 10 W |
| Ingress protection rating |
IP65 |
| Mounting method |
Wall mounting |
Grid connection in Germany. The AC power figures shown are equipment ratings. Before installation, a qualified electrical contractor verifies the documentation required for the specific unit and the connection requirements of the local grid operator.